Download PDF

Introduction

This guide shows how to connect a DIDLogic SIP trunk to RingQ. RingQ tested this setup automatically on 19 November 2026: registration, outbound and inbound calls, caller ID, DTMF and two-way voice all passed.

Most settings are filled in for you when you pick DIDLogic from the RingQ Supported SIP Template list.

DIDLogic configuration

  1. Sign in to your DIDLogic account.
  2. Create a SIP account (or use an existing one) and note its username and password.
  3. Point your phone numbers (DIDs) to this SIP account or trunk.
  4. Use one of your DIDLogic numbers as the outbound caller ID.

Tested settings

These are the settings RingQ proved in the automated test. The DIDLogic template already contains them.

SettingValue
SIP serversip.de.didlogic.net
Port5060
TransportUDP
Sign-inRegistration (username and password)
CodecsG.711 u-law (PCMU)
DTMFRFC 2833
Encrypted media (SRTP)No
Caller ID formatAs your numbers are written
Inbound number fromInvite

RingQ configuration

  1. Sign in to your RingQ web app as an administrator.
  2. Go to Settings > Call Flow > SIP.
  3. Click + in the top-right corner to add a Supported SIP Template.
  4. Select your country, then select DIDLogic.
  5. Enter the username and password of your DIDLogic SIP account.
  6. Enter the outbound caller ID you want to show.
  7. Click Save. The status turns green when the trunk is connected.

Outbound rule

  1. Go to Settings > Global > Outbound Rules and click Outbound Rule +.
  2. Enter a name and the number prefix this rule should match.
  3. Select the DIDLogic trunk as the route.
  4. Use the values below under Advanced, then click Save.
SettingValue
Strip digits0
PrependDefault
SIP from userDefault
SIP from display nameDefault
SIP from hostDefault
CID typeDefault

Inbound calls

  1. Go to Settings > Call Flow > Add DID and click Add DID +.
  2. Enter your DIDLogic number and select the DIDLogic trunk.
  3. Click Create, then drag the number to the extension, queue or IVR that should answer it.

If something does not work

  1. Status stays red: check the username, password and SIP server, and that your RingQ server can reach sip.de.didlogic.net on port 5060.
  2. Calls connect without audio: open the RingQ firewall ports (UDP 16384-32768 for voice).
  3. Wrong caller ID shown: send it without a leading +, as in the tested settings.
  4. Still stuck: contact RingQ support from your RingQ web app.