Configuring DIDLogic SIP Trunk
Download PDFIntroduction
This guide shows how to connect a DIDLogic SIP trunk to RingQ. RingQ tested this setup automatically on 19 November 2026: registration, outbound and inbound calls, caller ID, DTMF and two-way voice all passed.
Most settings are filled in for you when you pick DIDLogic from the RingQ Supported SIP Template list.
DIDLogic configuration
- Sign in to your DIDLogic account.
- Create a SIP account (or use an existing one) and note its username and password.
- Point your phone numbers (DIDs) to this SIP account or trunk.
- Use one of your DIDLogic numbers as the outbound caller ID.
Tested settings
These are the settings RingQ proved in the automated test. The DIDLogic template already contains them.
| Setting | Value |
|---|---|
| SIP server | sip.de.didlogic.net |
| Port | 5060 |
| Transport | UDP |
| Sign-in | Registration (username and password) |
| Codecs | G.711 u-law (PCMU) |
| DTMF | RFC 2833 |
| Encrypted media (SRTP) | No |
| Caller ID format | As your numbers are written |
| Inbound number from | Invite |
RingQ configuration
- Sign in to your RingQ web app as an administrator.
- Go to Settings > Call Flow > SIP.
- Click + in the top-right corner to add a Supported SIP Template.
- Select your country, then select DIDLogic.
- Enter the username and password of your DIDLogic SIP account.
- Enter the outbound caller ID you want to show.
- Click Save. The status turns green when the trunk is connected.
Outbound rule
- Go to Settings > Global > Outbound Rules and click Outbound Rule +.
- Enter a name and the number prefix this rule should match.
- Select the DIDLogic trunk as the route.
- Use the values below under Advanced, then click Save.
| Setting | Value |
|---|---|
| Strip digits | 0 |
| Prepend | Default |
| SIP from user | Default |
| SIP from display name | Default |
| SIP from host | Default |
| CID type | Default |
Inbound calls
- Go to Settings > Call Flow > Add DID and click Add DID +.
- Enter your DIDLogic number and select the DIDLogic trunk.
- Click Create, then drag the number to the extension, queue or IVR that should answer it.
If something does not work
- Status stays red: check the username, password and SIP server, and that your RingQ server can reach sip.de.didlogic.net on port 5060.
- Calls connect without audio: open the RingQ firewall ports (UDP 16384-32768 for voice).
- Wrong caller ID shown: send it without a leading +, as in the tested settings.
- Still stuck: contact RingQ support from your RingQ web app.